BIG-BAGS ABLEITFÄHIG TYP- C
BIG-BAGS ABLEITFÄHIG TYP-C
FIBC's Type-B FIBCs made from non-conductive materials having a breakdown voltage not exceeding 6 kV
Type B FIBC can be used where combustible dusts are present, but it shall not be used in hazardous areas, zones 1 or 0.Type B FIBC are permitted in Dust Zone 21-22 with MIE > 3 mJ (MIE = Minimum Ignition Energy).
When filling and emptying big bags, static electrical energy can be discharged, which can lead to an explosion in an explosive environment. Depending on the structure, conductivity and determinations, big bags can be divided into several groups according to the IEC 61340 standard:
BIG BAG Typ-A - FIBCs made from non-conductive materials without any measures against electrostatic charging. As no electrical conductive material is interwoven in the fabric grounding and charge dissipation is hardly possible. Explosive atmospheres of gases as well as explosive atmospheres of dusts can be ignited. Therefore, a Type A FIBC must not be used to handle combustible dusts. If such a FIBC containing inert material has to be used in hazardous areas, this may only happen in zones 2 or 22.
BIG BAG Typ-B - FIBCs made from non-conductive materials having a breakdown voltage not exceeding 6 kV. This reliably prevents the ignition of explosive dust atmospheres while explosive gas atmospheres can still be ignited. Like Type A, the Type B has no interwoven conductive materials. Thus, a Type B FIBC can be used where combustible dusts are present, but it shall not be used in hazardous areas, zones 1 or 0.Type B FIBC are permitted in Dust Zone 21-22 with MIE > 3 mJ (MIE = Minimum Ignition Energy).
BIG BAG Typ-C - FIBCs normally made of non-conductive fabric with interwoven conductive threads
-
forming a reliably interconnected grid of maximum 50 mm mesh size
or -
having a distance between each other of less than 20 mm if the threads are in one direction only.
Those conductive threads must be interconnected with less than 107 ohm and must be grounded during filling and emptying operations. Some Type C FIBCs have interconnected conductive loops to enable grounding via a (grounded) hoist system. When grounded properly there is no risk of incendive discharges.
The inner or outer surfaces of the FIBC may have a thin coating. In this case the breakdown voltage to the conductive threads must not exceed 6 kV to avoid propagating brush discharges.
Thus, Type C FIBCs can be used in an environment with combustible dusts and/or explosive gases. There is no risk using these FIBCs in hazardous areas zones 1, 2, 21, 22, providing they are properly grounded.
BIG-BAGS ANTISTATIC TYP-B
FIBC's Type-B FIBCs made from non-conductive materials having a breakdown voltage not exceeding 6 kV
Type B FIBC can be used where combustible dusts are present, but it shall not be used in hazardous areas, zones 1 or 0.Type B FIBC are permitted in Dust Zone 21-22 with MIE > 3 mJ (MIE = Minimum Ignition Energy).
When filling and emptying big bags, static electrical energy can be discharged, which can lead to an explosion in an explosive environment. Depending on the structure, conductivity and determinations, big bags can be divided into several groups according to the IEC 61340 standard:
BIG BAG Typ-A - FIBCs made from non-conductive materials without any measures against electrostatic charging. As no electrical conductive material is interwoven in the fabric grounding and charge dissipation is hardly possible. Explosive atmospheres of gases as well as explosive atmospheres of dusts can be ignited. Therefore, a Type A FIBC must not be used to handle combustible dusts. If such a FIBC containing inert material has to be used in hazardous areas, this may only happen in zones 2 or 22.
BIG BAG Typ-B - FIBCs made from non-conductive materials having a breakdown voltage not exceeding 6 kV. This reliably prevents the ignition of explosive dust atmospheres while explosive gas atmospheres can still be ignited. Like Type A, the Type B has no interwoven conductive materials. Thus, a Type B FIBC can be used where combustible dusts are present, but it shall not be used in hazardous areas, zones 1 or 0.Type B FIBC are permitted in Dust Zone 21-22 with MIE > 3 mJ (MIE = Minimum Ignition Energy).
BIG BAG Typ-C - FIBCs normally made of non-conductive fabric with interwoven conductive threads
-
forming a reliably interconnected grid of maximum 50 mm mesh size
or -
having a distance between each other of less than 20 mm if the threads are in one direction only.
Those conductive threads must be interconnected with less than 107 ohm and must be grounded during filling and emptying operations. Some Type C FIBCs have interconnected conductive loops to enable grounding via a (grounded) hoist system. When grounded properly there is no risk of incendive discharges.
The inner or outer surfaces of the FIBC may have a thin coating. In this case the breakdown voltage to the conductive threads must not exceed 6 kV to avoid propagating brush discharges.
Thus, Type C FIBCs can be used in an environment with combustible dusts and/or explosive gases. There is no risk using these FIBCs in hazardous areas zones 1, 2, 21, 22, providing they are properly grounded.
Fabric:
Uncoated fabric:
-
For filling material with bigger grain size such as granules, sand, stones, cereals...
-
The fabric is breathable and very suitable for susceptible food.
-
In a non-coated fabric, the ribbons may move, so an uncoated big-bag will always have a worse shape and stability to a coated big-bag.
Coated fabric:
-
For dusty or powdery filling materials.
-
The fabric is water repellent and dustproof.
-
A coated fabric big bag has better shape and stability.
Seams:
We offer the following seams:
-
Standard O/S seams without additional dustproof
-
One-side dustproof seams
-
Double dustproof seams
-
Double dustproof seams plus non woven webbing
Lifting loops:
Corner loops
Cross corner loops
Top and Bottom
Open top,
flat closed bottom
Open top,
bottom spout
Open top,
cone bottom
Open top,
total opening bottom
top skirt,
flat closed bottom
top skirt,
bottom spout
top skirt,
cone bottom
top skirt,
total opening bottom
top spout,
flat closed bottom
top spout,
bottom spout
top spout,
cone bottom
top spout,
total opening bottom